X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 277 (0.05 M citric acid, 0.05 M BIS-TRIS propane) pH 5 20% w/v PEG 3,350
Unit Cell:
a: 60.374 Å b: 100.420 Å c: 147.177 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.00 Solvent Content: 38.58
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.93 35.60 30472 2039 88.80 0.2209 0.2398 20.68
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.93 50 90 ? ? 19.59 5.7 ? 30885 ? ? 19.22
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.93 1.96 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-D 1.13 APS 21-ID-D
Software
Software Name Purpose Version
PHENIX refinement 1.21.2_5419
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .