Planned Maintenance: Some services may turn out to be unavailable from 15th January, 2026 to 16th January, 2026. We apologize for the inconvenience!

SOLUTION NMR


NMR Experiment
Experiment Type Sample Contents Ionic Strength Solvent pH Pressure Temprature (K)
1 1D 1H 2.78 mM uniform 15N LR4-814, 93% H2O/7% D2O 0 93% H2O/7% D2O 5 1 297
2 2D TOCSY (mix = 15 ms) 2.78 mM uniform 15N LR4-814, 93% H2O/7% D2O 0 93% H2O/7% D2O 5 1 297
3 2D TOCSY (mix = 60 ms) 2.78 mM uniform 15N LR4-814, 93% H2O/7% D2O 0 93% H2O/7% D2O 5 1 297
4 2D NOESY (mix = 200 ms) 2.78 mM uniform 15N LR4-814, 93% H2O/7% D2O 0 93% H2O/7% D2O 5 1 297
5 2D 1H-15N sofastHMQC 2.78 mM uniform 15N LR4-814, 93% H2O/7% D2O 0 93% H2O/7% D2O 5 1 297
6 3D 1H-1H-15N-NOESY-HSQC (mix = 200 ms) 2.78 mM uniform 15N LR4-814, 93% H2O/7% D2O 0 93% H2O/7% D2O 5 1 297
7 2D 1H-13C HSQC 2.78 mM uniform 15N LR4-814, 93% H2O/7% D2O 0 93% H2O/7% D2O 5 1 297
NMR Spectrometer Information
Spectrometer Manufacturer Model Field Strength
1 Bruker AVANCE NEO 700
NMR Refinement
Method Details Software
molecular dynamics ? 2
NMR Ensemble Information
Conformer Selection Criteria structures with the lowest energy
Conformers Calculated Total Number 40
Conformers Submitted Total Number 15
Representative Model 1 (lowest energy)
Computation: NMR Software
# Classification Version Software Name Author
1 data analysis ? TopSpin Bruker
2 structure calculation ? DYNAMO Delaglio and Kuszewski
Feedback Form
Name
Email
Institute
Feedback