X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.0 291 0.1 M Sodium chloride, 0.1 M Bis-tris propane pH 9.0, 20.5% w/v Polyethylene glycol 1,500
Unit Cell:
a: 155.894 Å b: 155.894 Å c: 155.894 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: I 21 3
Crystal Properties:
Matthew's Coefficient: 2.80 Solvent Content: 56.09
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.40 38.97 24758 2005 99.53 0.2297 0.2596 73.00
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.39 38.97 99.7 ? ? 22.8 40.7 ? 25022 ? ? 65.06
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.39 2.52 98.2 ? ? 2.0 38.7 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRL BEAMLINE BL9-2 0.9794 SSRL BL9-2
Software
Software Name Purpose Version
PHENIX refinement 1.21_5207
autoXDS data reduction .
SCALA data scaling .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback