Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
9NFM
pdb_00009nfm
10.2210/pdb9nfm/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
ABC transporter from yellowfin tuna bound to inhibitor molecule DDT
Specimen Preperation
Sample Aggregation State
2D ARRAY
Vitrification Instrument
SPT LABTECH CHAMELEON
Cryogen Name
ETHANE
Sample Vitrification Details
The grids were glow discharged for 80sec at 12mA, with a relative humidity of 82% and temperature 21.5oC maintained throughout preparation. Samples of purified protein were concentrated to 1mg/mL and ultracentrifuged in a Beckmann Optima Ultracentrifuge for 15 minutes prior to grid preparation. The sample was applied via 2-S application mode by the Chameleon, allowed to wick for 530ms via the grid nanowires, and subsequently plunged into liquid ethane maintained at -180oC.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
239981
Reported Resolution (Å)
3.89
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
RIGID BODY FIT
Refinement Target
?
Overall B Value
159
Fitting Procedure
?
Details
?
Data Acquisition
Detector Type
FEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å
2
)
55
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
TFS KRIOS
Minimum Defocus (nm)
1000
Maximum Defocus (nm)
2000
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
?
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
?
Nominal Magnification
?
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
PARTICLE SELECTION
cryoSPARC
v4.5.3
IMAGE ACQUISITION
cryoSPARC
v4.5.3
CTF CORRECTION
cryoSPARC
v4.5.3
MODEL FITTING
PHENIX
1.21.1_5286
MODEL REFINEMENT
PHENIX
1.21.1_5286
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
?