X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 0.02 M Citric acid, 0.08 M BIS-TRIS propane pH 8.8, 16% w/v Polyethylene glycol 3,350
Unit Cell:
a: 55.461 Å b: 98.659 Å c: 59.735 Å α: 90.000° β: 108.933° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.24 Solvent Content: 45.20
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT NONE 1.89 46.74 47862 1998 97.89 0.1851 0.2261 34.78
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.89 49.03 98.1 ? ? 8.5 7.6 ? 47952 ? ? 28.52
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.89 1.93 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.95365 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.14_3260
XDS data reduction .
Aimless data scaling .
PHASER phasing .
Feedback Form
Name
Email
Institute