9JF5

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 293 0.1 M sodium acetate buffer (pH 7.0), 12% w/v PEG 3350. The crystal was soaked in the reservoir solution with 1 mM L-arginine for 10 min before flash-cooling.
Unit Cell:
a: 134.020 Å b: 195.575 Å c: 196.124 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 3.45 Solvent Content: 64.36
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.90 47.44 200772 10043 99.81 0.1617 0.1889 31.27
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.90 50 99.8 0.082 ? 18.02 7.66 ? 200882 ? ? 27.23
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.90 2.02 99.2 ? ? 2.26 7.26 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SPRING-8 BEAMLINE BL26B1 1.00 SPring-8 BL26B1
Software
Software Name Purpose Version
PHENIX refinement 1.21.1_5286
XDS data reduction .
XDS data scaling .
PHENIX phasing .