X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 292 ANAEROBY (<1.5 ppm O2) 14% w/v PEG 4K 0.1M Mes pH 6.5 O.1M NaCl 0.1M MgCl2
Unit Cell:
a: 64.166 Å b: 77.226 Å c: 153.969 Å α: 90° β: 90° γ: 90°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.17 Solvent Content: 39
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD THROUGHOUT 2.417 76.98 23186 1118 77.2 0.2340 0.2761 89.58
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.417 76.985 92.4 0.1114 ? 16.52 23.30 ? 23186 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 7.431 76.985 100.0 ? ? 43.36 23.74 1159
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 2 1.7389 SOLEIL PROXIMA 2
Software
Software Name Purpose Version
autoPROC data processing 1.0.5 20240123
XDS data reduction Jun 30, 2023
Aimless data scaling 0.7.15
STARANISO data scaling 2.4.9
BUSTER refinement 2.10.4
PHASER phasing 2.8.2
PARROT phasing 1.0.4
CRANK2 phasing 2.0.281