9FQ1

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 1.8 M sodium chloride, 0.1 M sodium phosphate monobasic monohydrate, 0.1 M Potassium phosphate monobasic, 0.1 M Mes monohydrate (pH 6.5).
Unit Cell:
a: 68.053 Å b: 96.003 Å c: 116.805 Å α: 90.00° β: 98.20° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.57 Solvent Content: 52.07
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD FREE R-VALUE 2.600 14.992 45428 2186 99.49 0.1960 0.2431 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.6 15 99.6 ? ? 6.8 3.4 ? 52034 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.60 2.66 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID30B 0.979 ESRF ID30B
Software
Software Name Purpose Version
PHENIX refinement (1.14_3260: ???)
XDS data reduction .
XDS data scaling .
PHENIX phasing .