X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293.15 20% glycerol, 16% PEG 8K, 0.04M kaliumdihydrogenphosphate
Unit Cell:
a: 143.116 Å b: 143.116 Å c: 43.556 Å α: 90° β: 90° γ: 120°
Symmetry:
Space Group: P 64
Crystal Properties:
Matthew's Coefficient: 2.93 Solvent Content: 58.09
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.878 25.25 37910 1816 90.3 0.2217 0.2372 53.4
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.878 123.942 90.3 0.081 0.081 18.8 18.6 ? 37931 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.878 1.974 32.9 ? 2.601 1.4 20.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SLS BEAMLINE X06SA 1.000036 SLS X06SA
Software
Software Name Purpose Version
BUSTER refinement 2.11.8
autoPROC data reduction .
XDS data reduction Feb 5, 2021
autoPROC data scaling 1.1.7
Aimless data scaling .
STARANISO data scaling .
PHASER phasing .