ELECTRON MICROSCOPY


Sample

13pf E254Q microtubule from recombinant human tubulin decorated with EB3

Specimen Preperation
Sample Aggregation State HELICAL ARRAY
Vitrification Instrument FEI VITROBOT MARK IV
Cryogen Name ETHANE
Sample Vitrification Details ?
3D Reconstruction
Reconstruction Method HELICAL
Number of Particles 33410
Reported Resolution (Å) 4.3
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type HELICAL
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol RIGID BODY FIT
Refinement Target ?
Overall B Value 190
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type FEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å2) 7.19
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model TFS GLACIOS
Minimum Defocus (nm) 700
Maximum Defocus (nm) 2200
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS ?
Imaging Mode BRIGHT FIELD
Specimen Holder Model ?
Nominal Magnification ?
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 200
Imaging Details ?
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION RELION 3.1.2
CTF CORRECTION RELION 3.1.2
MODEL FITTING Coot 0.9.8.92
MODEL REFINEMENT PHENIX 1.21
CLASSIFICATION RELION 3.1.2
RECONSTRUCTION PHENIX 1.21
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION ?