9EU1

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 293 0.2M Ammonium sulphate 0.1M Bis-tris pH 7.5 2.2M Ammonium sulphate
Unit Cell:
a: 139.167 Å b: 139.167 Å c: 110.233 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 3.17 Solvent Content: 61.26
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.92 40.67 93804 2009 99.79 0.1839 0.2140 46.96
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.92 40.67 99.77 0.1127 ? 17.43 20.8 ? 93816 ? ? 40.79
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.92 1.989 99.60 ? ? 1.46 21.0 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-2 0.8731 ESRF ID23-2
Software
Software Name Purpose Version
PHENIX refinement 1.20.1_4487
autoPROC data reduction .
XSCALE data scaling .
PHASER phasing .