ELECTRON MICROSCOPY


Sample

Yeast post-catalytic P complex spliceosome

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument FEI VITROBOT MARK IV
Cryogen Name ETHANE
Sample Vitrification Details ?
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 209005
Reported Resolution (Å) 2.31
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol FLEXIBLE FIT
Refinement Target ?
Overall B Value ?
Fitting Procedure ?
Details After fixing in ISOLDE, the model was refined in phenix.real_space_refine with the following non-default flags: refinement { run = *minimization_global rigid_body local_grid_search morphing simulated_annealing *adp } reference_model { enabled = True use_starting_model_as_reference = True fix_outliers = False strict_rotamer_matching = True } pdb_interpretation { reference_coordinate_restraints { enabled = True exclude_outliers = False top_out = True } automatic_linking { link_metals = True } peptide_link { restrain_rama_outliers = False restrain_rama_allowed = False } ramachandran_plot_restraints { enabled = False } }
Data Acquisition
Detector Type GATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å2) 40
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model TFS KRIOS
Minimum Defocus (nm) 1300
Maximum Defocus (nm) 3100
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification 130000
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details ?
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION Topaz ?
IMAGE ACQUISITION EPU ?
CTF CORRECTION CTFFIND 4.1
MODEL FITTING Coot 0.9.8.3
INITIAL EULER ASSIGNMENT RELION 5.0
FINAL EULER ASSIGNMENT RELION 5.0
CLASSIFICATION RELION 5.0
RECONSTRUCTION RELION 5.0
MODEL REFINEMENT ISOLDE 1.7
MODEL REFINEMENT PHENIX ?
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION ?