9CLN

ELECTRON MICROSCOPY


Sample

Human adenovirus 5 (Ad5) in complex with Coagulation factor FII

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument ?
Cryogen Name ETHANE
Sample Vitrification Details ?
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 2324
Reported Resolution (Å) 4.13
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space ?
Refinement Protocol RIGID BODY FIT
Refinement Target ?
Overall B Value ?
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type GATAN K3 BIOCONTINUUM (6k x 4k)
Electron Dose (electrons/Å2) 81
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model FEI TITAN KRIOS
Minimum Defocus (nm) 2500
Maximum Defocus (nm) 4000
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification 81000
Calibrated Magnification 81000
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details ?
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION RELION 4.0
IMAGE ACQUISITION EPU ?
CTF CORRECTION CTFFIND 4
MODEL FITTING Coot 0.9.8
MODEL REFINEMENT PHENIX ?
INITIAL EULER ASSIGNMENT RELION 4
FINAL EULER ASSIGNMENT RELION 4
CLASSIFICATION RELION 4
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
NONE ?