Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
9CL9
pdb_00009cl9
10.2210/pdb9cl9/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
WT 12C 50S ribosomal subunit assembly intermediate
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
3 microliter of the sample was added.
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
22502
Reported Resolution (Å)
5.04
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
OTHER
Refinement Target
Comprehensive validation (cryo-EM)
Overall B Value
118.80
Fitting Procedure
?
Details
The atomic model was fitted into a low resolution (5 angstrom) EM map; therefore the coordinates should only serve as a general visual representation and should not be looked into detail. Initial docking of the atomic model was done in ChimeraX. Coot and Phenix were used for real-space refinements. Geometry minimization in Phenix was used to improve the RNA atomic model.
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å
2
)
50
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TALOS ARCTICA
Minimum Defocus (nm)
1000
Maximum Defocus (nm)
2000
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
?
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
?
Nominal Magnification
36000
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
200
Imaging Details
In order to account for highly preferred orientation of the specimen, data were acquired using tilts at -20 degrees.
Imaging Experiment
Task
Software Package
Version
PARTICLE SELECTION
cryoSPARC
?
IMAGE ACQUISITION
Leginon
?
MODEL FITTING
UCSF ChimeraX
?
RECONSTRUCTION
cryoSPARC
?
MODEL REFINEMENT
Coot
?
MODEL REFINEMENT
PHENIX
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
NONE
CTF correction were performed by Patch CTF Estimation of cryoSPARC