SOLUTION NMR


NMR Experiment
Experiment Type Sample Contents Ionic Strength Solvent pH Pressure Temprature (K)
1 2D 1H-1H NOESY 300 uM LBT3, 600 uM LANTHANUM (III) ION, 50 mM D13 MES, 100 mM sodium chloride, 90% H2O/10% D2O 100 90% H2O/10% D2O 6 1 298
2 2D 1H-1H TOCSY 300 uM LBT3, 600 uM LANTHANUM (III) ION, 50 mM D13 MES, 100 mM sodium chloride, 90% H2O/10% D2O 100 90% H2O/10% D2O 6 1 298
3 2D 1H-13C HSQC 300 uM LBT3, 600 uM LANTHANUM (III) ION, 50 mM D13 MES, 100 mM sodium chloride, 90% H2O/10% D2O 100 90% H2O/10% D2O 6 1 298
4 2D 1H-15N HSQC 300 uM LBT3, 600 uM LANTHANUM (III) ION, 50 mM D13 MES, 100 mM sodium chloride, 90% H2O/10% D2O 100 90% H2O/10% D2O 6 1 298
NMR Spectrometer Information
Spectrometer Manufacturer Model Field Strength
1 Bruker AVANCE III HD 800
NMR Refinement
Method Details Software
simulated annealing ? 5
NMR Ensemble Information
Conformer Selection Criteria target function
Conformers Calculated Total Number 100
Conformers Submitted Total Number 20
Representative Model 1 (lowest energy)
Computation: NMR Software
# Classification Version Software Name Author
1 structure calculation 3.98.15 CYANA Guntert, Mumenthaler and Wuthrich
2 chemical shift assignment 3.1 CcpNmr Analysis CCPN
3 processing 3.6 TopSpin Bruker Biospin
4 peak picking 3.1 CcpNmr Analysis Assign CCPN
5 refinement 2016.3 GROMACS GROMACS