Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Documentation
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
9B9V
pdb_00009b9v
10.2210/pdb9b9v/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
ZBTB9 BTB domain filament
Specimen Preperation
Sample Aggregation State
FILAMENT
Vitrification Instrument
LEICA EM GP
Cryogen Name
ETHANE
Sample Vitrification Details
Grids were vitrified using a Leica EM GP plunge freezer operated at 90% humidity and 10 C with 10 s pre-blot, 3 s blot, 3 s post-blot.
3D Reconstruction
Reconstruction Method
HELICAL
Number of Particles
147135
Reported Resolution (Å)
8.1
Resolution Method
FSC 0.143 CUT-OFF
Other Details
Asymmetric helical refinement followed by local refinement led to the final reconstruction. The helical symmetry values represent the angular rotation and axial rise for two dimers at the core of the map, where the local resolution was the highest. These values, however, were not applied during helical refinement as they did not improve the quality of the final reconstruction.
Refinement Type
Symmetry Type
HELICAL
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
OTHER
Refinement Target
?
Overall B Value
762
Fitting Procedure
?
Details
Real-space refinement without local grid search
Data Acquisition
Detector Type
GATAN K3 (6k x 4k)
Electron Dose (electrons/Å
2
)
50.1
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TALOS ARCTICA
Minimum Defocus (nm)
800
Maximum Defocus (nm)
2000
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
36000
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
200
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
MODEL REFINEMENT
PHENIX
1.21.1_5286
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
?
Feedback
Feedback Form
Name
Email
Institute
Feedback
Submit