8XIS

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5 293 10 mg/ml protein solution was mixed 1:11 with an optimized solution consisting of 100 mM pH 5.0 sodium acetate, 12% PEG4000, and 5% glycerol with streak seeding
Unit Cell:
a: 82.277 Å b: 88.520 Å c: 88.540 Å α: 98.407° β: 110.691° γ: 110.652°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.38 Solvent Content: 48.36
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.68 43.44 229939 11539 96.99 0.1899 0.2295 32.88
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.68 43.44 96.99 ? ? 13.69 3.5 ? 229962 ? ? 23.42
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.68 1.74 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 95 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-5A 1.0000 Photon Factory BL-5A
Software
Software Name Purpose Version
PHENIX refinement 1.21rc1_5127
XDS data reduction .
Aimless data scaling .
PHENIX phasing .