X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 295 100 mM Sodium Acetate, pH 4.5, 20% w/v Polyethylene Glycol 3000
Unit Cell:
a: 62.416 Å b: 165.240 Å c: 47.928 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.62 Solvent Content: 53.17
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.30 58.46 14652 753 67.45 0.21789 0.26161 43.693
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.300 58.46 94.4 0.139 ? 8.1 8.1 ? 15406 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.300 2.468 91.9 ? ? ? 7.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-1 0.972423 ESRF ID23-1
Software
Software Name Purpose Version
REFMAC refinement 5.8.0419
autoPROC data reduction .
autoPROC data scaling .
PHASER phasing .