ELECTRON MICROSCOPY


Sample

Quaternary complex of RM, S and DNA complex

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument FEI VITROBOT MARK IV
Cryogen Name ETHANE
Sample Vitrification Details ?
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 244448
Reported Resolution (Å) 3.06
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol FLEXIBLE FIT
Refinement Target ?
Overall B Value ?
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type DIRECT ELECTRON DE-10 (5k x 4k)
Electron Dose (electrons/Å2) 40
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model FEI TALOS ARCTICA
Minimum Defocus (nm) 1200
Maximum Defocus (nm) 5000
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification ?
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 200
Imaging Details ?
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION cryoSPARC 3.3
IMAGE ACQUISITION SerialEM 3
CTF CORRECTION cryoSPARC 3.3
MODEL FITTING Coot 0.9.8.9.2EL
IMAGE ACQUISITION SerialEM 4
INITIAL EULER ASSIGNMENT cryoSPARC 3.3
FINAL EULER ASSIGNMENT cryoSPARC 3.3
CLASSIFICATION cryoSPARC 3.3
RECONSTRUCTION cryoSPARC 3.3
MODEL REFINEMENT PHENIX 1.19.2
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
NONE ?