8VF0

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.4 289.15 The crystallization buffer was 100 mM Bis-Tris buffer (adjusted to pH 5.0-5.75 with acetic acid), 0.2 M magnesium acetate and 20-32% PEG 3350
Unit Cell:
a: 44.694 Å b: 51.593 Å c: 78.507 Å α: 90.00° β: 93.17° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.03 Solvent Content: 39.26
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.028 44.626 23233 1162 99.44 0.1944 0.2354 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.028 44.63 99.4 0.278 ? 4.3 6.8 ? 23301 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.03 2.08 ? 95.4 ? ? 6.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX1 0.95373 Australian Synchrotron MX1
Software
Software Name Purpose Version
PHENIX refinement (1.11.1_2575: ???)
Aimless data scaling .
XDS data reduction .
PHASER phasing .