8V9A

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 291.15 0.2 M Magnesium chloride hexahydrate 0.1 M Tris (Ph 7.0) 10% w/v PEG 8000
Unit Cell:
a: 62.704 Å b: 71.156 Å c: 78.386 Å α: 90.00° β: 110.04° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: ? Solvent Content: ?
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.67 45.38 75383 3763 99.40 0.1865 0.2128 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.67 45.38 99.5 0.135 ? 6.3 4.6 ? 75438 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.67 1.69 ? 92.5 ? ? 4.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.95373 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement (1.19.2_4158: ???)
XDS data reduction .
Aimless data scaling .
PHASER phasing .