X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 The protein was set up in MRC2 plates in 100 nL plus 100 nL drops with the protein at 5 mg/mL with reservoir solutions being 2.6 to 2.9 M ammonium sulfate and 100 mM Tris buffer at pH 8.3 to 8.9
Unit Cell:
a: 41.985 Å b: 41.414 Å c: 72.309 Å α: 90.000° β: 103.968° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.09 Solvent Content: 41.07
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.215 39.664 70773 3563 97.169 ? 0.1430 15.420
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.21 41.4 97.5 0.072 ? 12.4 6.7 ? 70793 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.21 1.24 83.5 ? ? 2.3 6.3 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.953659 Australian Synchrotron MX2
Software
Software Name Purpose Version
REFMAC refinement 5.8.0419
XDS data reduction .
Aimless data scaling .
PHASER phasing .