X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 289.15 13uL 10mg/ml FphH (10mM HEPES pH 7.5, 100mM NaCl) were mixed with 5uL N34 (50mM in DMSO) and incubated at RT for ~1 hour. 0.2ul FphH-N34 were mixed with 0.2ul of reservoir solution. Sitting drop reservoir contained 180mM Calcium acetate hydrate, 100mM Tris pH 7.5, 9% w/v PEG 8000 and 9% w/v PEG 1000. Crystal was frozen in a solution of ~25% Ethylenglycol, 75% reservoir.
Unit Cell:
a: 67.381 Å b: 67.381 Å c: 55.473 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 43
Crystal Properties:
Matthew's Coefficient: 2.22 Solvent Content: 44.65
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.39 47.65 50356 2494 99.84 0.1614 0.1825 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.39 47.65 99.9 0.059 ? 23.0 13.5 ? 50414 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.39 1.41 ? 97.9 ? ? 12.9 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX1 0.9537 Australian Synchrotron MX1
Software
Software Name Purpose Version
PHENIX refinement 1.20.1_4487
Aimless data scaling 0.7.8
XDS data reduction 20220820
PHASER phasing 2.8.3
Feedback Form
Name
Email
Institute
Feedback