X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 291 19% PEG 8000, 0.55 M Lithium sulfate
Unit Cell:
a: 154.305 Å b: 154.305 Å c: 37.114 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 42 21 2
Crystal Properties:
Matthew's Coefficient: 3.33 Solvent Content: 63.04
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.73 69.01 47499 2441 99.80 0.2082 0.2364 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.73 109.11 100 0.1254 ? 16.93 14.2 ? 47590 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.73 1.76 97.75 ? ? 0.95 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 80 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-E 0.97918 APS 24-ID-E
Software
Software Name Purpose Version
PHENIX refinement 1.20.1_4487
DIALS data reduction .
Aimless data scaling .
PHENIX phasing .