8RGJ

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.5 292 Ammonium sulfate/Sodium fluoride/Sodium acetate
Unit Cell:
a: 135.85 Å b: 135.85 Å c: 78.634 Å α: 90° β: 90° γ: 90°
Symmetry:
Space Group: P 4 21 2
Crystal Properties:
Matthew's Coefficient: 2.32 Solvent Content: 46.93
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION FOURIER SYNTHESIS THROUGHOUT 2.359 96.06 20930 1045 67.7 0.2609 0.2779 55.62
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.359 96.060 93.7 0.3139 ? 12.42 25.61 ? 20930 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 7.631 96.060 99.8 ? ? 43.69 22.69 1047
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 2 0.98011 SOLEIL PROXIMA 2
Software
Software Name Purpose Version
autoPROC data processing .
autoPROC data processing Jan 10, 2022
Aimless data scaling 0.7.4
autoPROC data processing 2.3.63
BUSTER refinement 2.10.4
autoPROC data reduction .
FFT phasing .