8ORP

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 291 20 % (v/v) PEG monomethyl ether 550, 0.1 M sodium chloride, 0.1 M bicine buffer (pH 9.0) and 10 mM strontium chloride. Soak in a solution containing 10 mM acarbose.
Unit Cell:
a: 80.080 Å b: 72.540 Å c: 98.210 Å α: 90.000° β: 98.410° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.62 Solvent Content: 53.10
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION FOURIER SYNTHESIS FREE R-VALUE 2.00 29.57 75156 3759 99.76 0.1760 0.2116 18.94
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 29.6 99.8 ? ? 9.0 3.7 ? 75240 ? ? 17.57
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.0 2.1 99.7 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-1 0.9334 ESRF ID14-1
Software
Software Name Purpose Version
PHENIX refinement 1.20.1_4487
XDS data reduction .
XSCALE data scaling .
PHENIX phasing .