8OID

ELECTRON MICROSCOPY


Sample

Actin filament harboring the N111S mutation.

Specimen Preperation
Sample Aggregation State FILAMENT
Vitrification Instrument FEI VITROBOT MARK IV
Cryogen Name ETHANE-PROPANE
Sample Vitrification Details ?
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 1756928
Reported Resolution (Å) 2.30
Resolution Method FSC 0.143 CUT-OFF
Other Details The final refinement was performed from local searches in RELION.
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol FLEXIBLE FIT
Refinement Target ?
Overall B Value ?
Fitting Procedure ?
Details chain C of pdb 8A2T (including all water molecules) was fit in the central actin subunit of the density map. After substitution of all alpha-actin specific amino-acids to the corresponding beta-actin residues, introducing the N111S mutation, and further manual model building in Coot, the resulting model was fitted in four more actin subunits (chains A, B, D, E) in the density map. The filament was modeled as a pentamer to capture the full interaction interface of the central subunit with its four neighboring subunits. All water molecules were first manually built, inspected and adjusted in the central subunit, and were then copied to the other chains with non-crystallographic symmetry (NCS). Because the local resolution was worse at the periphery of the reconstruction, we removed water molecules that displayed poor corresponding cryo-EM density in the non-central actin chains. The model was refined in Phenix real-space refine with NCS restraints but without Ramachandran and rotamer restraints.
Data Acquisition
Detector Type GATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å2) 70
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model FEI TITAN KRIOS
Minimum Defocus (nm) 800
Maximum Defocus (nm) 2000
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification 130000
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details Titan Krios G3 microscope was aligned using Sherpa (FEI). Data collected in superresolution mode.
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION crYOLO 1.5.8
IMAGE ACQUISITION EPU ?
CTF CORRECTION CTFFIND 4.13
MODEL FITTING Coot 0.9.8.1
INITIAL EULER ASSIGNMENT SPHIRE 1.4
FINAL EULER ASSIGNMENT RELION 3.1.0
CLASSIFICATION RELION 3.1.0
RECONSTRUCTION RELION 3.1.0
MODEL REFINEMENT PHENIX 1.20.1-4487-000
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION ?