X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.0 297 200 mM magnesium chloride, 100 mM Tris-HCl, 28% (w/v) PEG400
Unit Cell:
a: 127.888 Å b: 127.888 Å c: 171.292 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: I 4 2 2
Crystal Properties:
Matthew's Coefficient: 3.70 Solvent Content: 66.78
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.55 45.22 43288 3755 97.79 0.1859 0.2156 50.67
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.55 45.22 98.7 0.112 ? 15.1 7.6 ? 43288 ? ? 46.69
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.55 2.66 99.6 ? ? 2.3 7.9 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-1A 1.03500 Photon Factory BL-1A
Software
Software Name Purpose Version
PHENIX refinement 1.17.1_3660
XDS data reduction .
Aimless data scaling .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback