X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.4 289 0.2 M magnesium acetate, 100 mM Bis-Tris buffer (adjusted with acetic acid to pH 5.0-5.75) and 20 - 32 % PEG 3350
Unit Cell:
a: 41.168 Å b: 51.615 Å c: 79.456 Å α: 90.00° β: 92.15° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.1 Solvent Content: 41.42
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT NONE 2.02 41.14 21644 1992 98.10 0.2000 0.2469 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.02 41.14 0.963 0.105 ? 0.174 6.6 ? 21694 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.02 2.07 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX1 0.9537 Australian Synchrotron MX1
Software
Software Name Purpose Version
PHENIX refinement (1.17.1_3660: ???)
Aimless data scaling .
iMOSFLM data reduction .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback