X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.6 293 0.2 M ammonium sulfate, 0.1 M sodium acetate pH 4.6, 25% (w/v) polyethylene glycol 4000
Unit Cell:
a: 78.543 Å b: 140.387 Å c: 142.095 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.29 Solvent Content: 46.32
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.2100 49.9300 31353 1550 78.6400 0.2368 0.2849 38.4557
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.200 50.000 96.400 0.131 ? 5.700 6.500 ? 38288 ? ? 32.560
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.200 2.240 96.100 ? ? ? 6.300 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 23-ID-B 1.03317 APS 23-ID-B
Software
Software Name Purpose Version
PHENIX refinement 1.19.2_4158
HKL-2000 data scaling .
PDB_EXTRACT data extraction 3.27
HKL-2000 data reduction .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback