X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 11% PEG 8000, 15-20% ethylene glycol, 0.1 M MES (pH 6.5), 5% 6-aminohexanoic acid
Unit Cell:
a: 45.040 Å b: 65.950 Å c: 55.230 Å α: 90.000° β: 100.390° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.37 Solvent Content: 48.02
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.6200 41.9300 25476 1216 62.5000 0.2020 0.2320 31.9900
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.62 54.32 86.4 ? ? 10.2 4.2 ? 25476 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.62 1.76 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON DIAMOND BEAMLINE I24 0.9795 Diamond I24
Software
Software Name Purpose Version
BUSTER refinement 2.11.7
PDB_EXTRACT data extraction 3.27
autoPROC data reduction .
autoPROC data scaling .
REFMAC phasing .
Feedback Form
Name
Email
Institute
Feedback