8CP4

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 298 4.1 M NaCl, 0.1 M HEPES pH 7.5, 10 % Glycerol
Unit Cell:
a: 186.170 Å b: 212.690 Å c: 196.740 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 4.73 Solvent Content: 74.01
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 3.19 47.87 64593 3230 99.53 0.2182 0.2525 140.55
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.19 47.87 99.6 ? ? 7.60 7.8 ? 64718 ? ? 128.14
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 9.42 47.87 98 ? ? 25.26 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 1 0.978565 SOLEIL PROXIMA 1
Software
Software Name Purpose Version
MxCuBE data collection Dec, 2020
XDS data reduction Dec, 2020
XDS data scaling Dec, 2020
PHENIX phasing Jan 31, 2020
PHENIX model building Jan 31, 2020
PHENIX refinement 1.20.1-4487