8CAW

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8 292 PEG 4000, Tris-HCl
Unit Cell:
a: 104.124 Å b: 51.093 Å c: 102.087 Å α: 90.00° β: 109.09° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.28 Solvent Content: 46.04
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.256 18.38 91941 4568 66.6 0.1703 0.1913 21.18
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.256 49.2 91.8 0.069 ? 9.5 3.9 ? 436693 ? ? 13.85
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.256 1.27 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 1 0.98010 SOLEIL PROXIMA 1
Software
Software Name Purpose Version
BUSTER refinement 2.10.4 (21-NOV-2022)
autoPROC data processing 1.0.5 20200520
autoPROC data processing Jan 31, 2020
autoPROC data processing 2.3.36
Aimless data scaling 0.7.4
autoPROC data reduction .
STARANISO data scaling .
PHASER phasing .