7YH3

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 293 00 mM HEPES pH 7.5 250 mM Mg(HCO2)2 18% PEG 3350
Unit Cell:
a: 68.387 Å b: 62.060 Å c: 69.324 Å α: 90.000° β: 100.460° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.00 Solvent Content: 38.48
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.7000 19.4800 51122 2486 81.3100 0.2185 0.2584 26.2237
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.7 20.0 94.9 0.048 ? 22.9 3.8 ? 51122 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.7 1.73 ? ? ? 2.2 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSRRC BEAMLINE TPS 05A 1 NSRRC TPS 05A
Software
Software Name Purpose Version
PHENIX refinement 1.17.1_3660
PDB_EXTRACT data extraction 3.27
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .