X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 291.15 2.4 M sodium malonate pH 7.0
Unit Cell:
a: 155.343 Å b: 155.343 Å c: 107.061 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: I 4
Crystal Properties:
Matthew's Coefficient: 4.81 Solvent Content: 74.41
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.6020 38.8360 39030 1996 99.7700 0.2089 0.2275 54.5658
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.600 50.000 100.000 0.100 ? 4.700 6.800 ? 39114 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.600 2.640 100.000 ? ? ? 6.800 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 193.15 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL18U1 0.9792 SSRF BL18U1
Software
Software Name Purpose Version
HKL-2000 data scaling .
PHENIX refinement 1.14_3247
PDB_EXTRACT data extraction 3.27
HKL-3000 data reduction .
PHENIX phasing .