X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 291 0.1M MES (pH 6.4), 50mM sodium acetate, 10mM MgCl2, 2% glycerol, 8% PEG 4000
Unit Cell:
a: 41.927 Å b: 63.632 Å c: 74.505 Å α: 79.140° β: 89.500° γ: 88.800°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 3.24 Solvent Content: 62.01
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.7980 30.9090 68018 2010 96.7300 0.1629 0.1826 33.4998
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.798 50 96.79 0.087 0.063 23.23 3.8 ? 68050 ? ? 21.65
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.798 1.83 95.9 ? 0.692 ? 3.7 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL17U1 0.97918 SSRF BL17U1
Software
Software Name Purpose Version
PHENIX refinement 1.15.2_3472
PDB_EXTRACT data extraction 3.27
HKL-3000 data reduction .
HKL-3000 data scaling .
PHENIX phasing .
Feedback Form
Name
Email
Institute
Feedback