X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 277 0.2 M calcium acetate, 0.1 M imidazole/HCl (pH 8.0), and 10% (w/v) polyethylene glycol 8000
Unit Cell:
a: 74.641 Å b: 50.573 Å c: 90.968 Å α: 90.000° β: 104.980° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.31 Solvent Content: 46.65
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.6000 33.8400 85167 4172 97.8700 0.1671 0.1872 18.2242
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.6 33.84 97.99 0.046 ? 20.74 3.4 ? 85167 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.60 1.66 ? ? ? 5.53 3.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL18U1 0.979 SSRF BL18U1
Software
Software Name Purpose Version
PHENIX refinement 1.17.1_3660
PDB_EXTRACT data extraction 3.27
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing .
Feedback Form
Name
Email
Institute
Feedback