Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
7USF
ELECTRON MICROSCOPY
Sample
MMTV strand transfer complex intasome
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
HOMEMADE PLUNGER
Cryogen Name
ETHANE
Sample Vitrification Details
Cryo-EM grids were prepared by freezing using a manual plunger in cold room at 4C
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
50196
Reported Resolution (Å)
3.5
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
FLEXIBLE FIT
Refinement Target
CC
Overall B Value
?
Fitting Procedure
?
Details
Initial model building was accomplished by rigid-body fitting of the MMTV CSC structure downloaded from the Protein Data Bank (PDB ID: 3JCA) into the EM map in Chimera 1.14 by Fit in Map tool. Unmodeled protein and DNA residues were manually built in Coot 0.9.4.1 and the structure underwent a few iterative cycles of manual model re-building and real-space refinement in Phenix. Ramachandran and secondary structure restraints were applied. To model the full octameric intasome, we additionally rigid-body docked the flanking IN dimers (PDB ID: 5CZ2) into the map. The density connecting the flanking dimers and the core was evident, but broken, and therefore a model was not derived for the linker regions. The final model accounts for the complete octameric MMTV STC intasome with connections for the linker regions.
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å
2
)
67
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
1000
Maximum Defocus (nm)
3000
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
22500
Calibrated Magnification
38167
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
IMAGE ACQUISITION
Leginon
?
CTF CORRECTION
cryoSPARC
3.0
MODEL FITTING
PHENIX
dev-4213-000
INITIAL EULER ASSIGNMENT
cryoSPARC
2.4
FINAL EULER ASSIGNMENT
cryoSPARC
2.4
RECONSTRUCTION
cryoSPARC
3.0
MODEL REFINEMENT
Coot
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
?