7UJY

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 298.15 PEG 3,350, Tris pH 7.5, MgCl2
Unit Cell:
a: 58.343 Å b: 58.343 Å c: 274.652 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 32
Crystal Properties:
Matthew's Coefficient: 2.240 Solvent Content: 45.040
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.7000 49.6900 105602 5294 91.9000 0.1900 0.2240 21.8500
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.700 50.000 99.000 ? ? 20.000 4.000 ? 105602 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.700 1.720 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100.000 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 19-BM 0.987 APS 19-BM
Software
Software Name Purpose Version
PHENIX refinement 1.9_1692
PDB_EXTRACT data extraction 3.27
HKL-3000 data reduction .
HKL-3000 data scaling .
PHENIX phasing .