X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 291 TPP riboswitch RNA (0.2 mM) 17 (2 mM) were heated in a buffer containing 50 mM potassium acetate (pH 6.8) and 5 (compound 17) mM MgCl2. Reservoir solution containing 0.1 M sodium acetate (pH 4.8), 0.35 M ammonium acetate, and 28% (v/v) PEG4000
Unit Cell:
a: 148.734 Å b: 30.400 Å c: 95.570 Å α: 90.000° β: 93.513° γ: 90.000°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.07 Solvent Content: 40.59
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.21 29.78 21817 1073 99.03 0.2062 0.2446 53.16
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.21 29.78 99.2 0.080 ? 10.4 4.0 ? 21835 ? ? 42.91
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.21 2.27 91.4 ? ? 1.6 3.7 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS-II BEAMLINE 17-ID-2 0.9184 NSLS-II 17-ID-2
Software
Software Name Purpose Version
PHENIX refinement 1.14-3260
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing 1.14_3260
Coot model building .
Feedback Form
Name
Email
Institute
Feedback