7TZM

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.4 289.15 For crystallisation, CYP199A4 was concentrated to approx. 40 mg mL-1 in 50 mM Tris buffer, pH 7.4. The crystallisation buffer was 100 mM Bis-Tris buffer (adjusted to pH 5.0-5.75 with acetic acid), 0.2 M magnesium acetate and 20-32% PEG 3350.
Unit Cell:
a: 44.231 Å b: 51.313 Å c: 78.892 Å α: 90.000° β: 91.930° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.01 Solvent Content: 38.71
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.5240 43.0080 53506 2006 98.8400 0.1873 0.2120 17.9414
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.520 43.010 99.000 0.186 ? 6.900 6.400 ? 53573 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.520 1.550 84.200 ? ? ? 5.900 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.95373 Australian Synchrotron MX2
Software
Software Name Purpose Version
XDS data reduction .
Aimless data scaling 0.7.4
PHASER phasing 2.8.2
PHENIX refinement 1.11.1-2575
PDB_EXTRACT data extraction 3.27