ELECTRON MICROSCOPY


Sample

Human adenovirus 26

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument GATAN CRYOPLUNGE 3
Cryogen Name ETHANE
Sample Vitrification Details Blot for 3 seconds before plunging
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 30834
Reported Resolution (Å) 3.38
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space REAL
Refinement Protocol RIGID BODY FIT
Refinement Target Correlation coefficient
Overall B Value 150
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å2) 53
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model FEI TITAN
Minimum Defocus (nm) 800
Maximum Defocus (nm) 3000
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification 22500
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details ?
Imaging Experiment
Task Software Package Version
IMAGE ACQUISITION Leginon ?
CTF CORRECTION CTFFIND 4.0
MODEL FITTING Coot ?
INITIAL EULER ASSIGNMENT cisTEM ?
CLASSIFICATION cisTEM ?
RECONSTRUCTION cisTEM ?
MODEL REFINEMENT PHENIX ?
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
NONE ?