X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 298 0.1 M bis-tris hydrochloride (pH 6.5), 0.245 M magnesium formate, 22% (w/v) PEG3350
Unit Cell:
a: 118.840 Å b: 118.840 Å c: 127.440 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: I 41 2 2
Crystal Properties:
Matthew's Coefficient: 3.5 Solvent Content: 64
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 2.89 49.05 10519 1032 99.72 0.1908 0.2202 119.92
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.889 49.05 99.68 0.044 ? 30.28 13.09 ? 11082 ? ? 116.29
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.889 2.993 97.74 ? ? 1.79 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.95 Australian Synchrotron MX2
Software
Software Name Purpose Version
PHENIX refinement 1.13_2998
PHENIX refinement 1.13_2998
XDS data reduction .
Aimless data scaling .
Auto-Rickshaw phasing .