X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 11% PEG 8000, 15-20% ethylene glycol, 0.1 M MES (pH 6.5), 5% 6-aminohexanoic acid
Unit Cell:
a: 45.091 Å b: 65.882 Å c: 54.923 Å α: 90.000° β: 102.520° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.34 Solvent Content: 47.34
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.1190 53.617 12552 609 69.9000 0.1980 0.2525 48.4000
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.119 53.617 87.8 ? ? 7.2 3.5 ? 12552 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.119 2.295 ? ? ? 1.4 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 18-ID 1.000 APS 18-ID
Software
Software Name Purpose Version
BUSTER refinement 2.11.7 (20-MAY-2020)
PDB_EXTRACT data extraction 3.27
XDS data reduction .
autoPROC data scaling .
autoBUSTER phasing .