Home
About
Browse
Covid-19
Organism Classification
Alphafold Collection
Virus Classification
Indian Data
Contact
Search Type
PDB Id
Uniprot Id
Source Organism
Host Organism
Protein Name
Method
Summary
Structure Feature
Experiment
Ligands & Environment
7S7B
pdb_00007s7b
10.2210/pdb7s7b/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
human Nuclear Exosome Targeting (NEXT)-RNA substrate 1 complex
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
30 s wait time, blot for 2.5 s before plunging
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
618412
Reported Resolution (Å)
4.06
Resolution Method
FSC 0.143 CUT-OFF
Other Details
A total of 618,412 particles were used for the consensus reconstruction with an overall resolution of 4.06 Angstrom (FSC 0.143 cut off). Focused 3D classification and local refinement were performed in several regions of the complex. A composite map was generated using focused reconstructions of ZCCHC8 HD/KID-MTR4 KOW (3.26 Angstrom, FSC = 0.143; 117,561 particles), protomer A MTR4 (3.42 Angstrom, FSC = 0.143; 225,213 particles), protomer B MTR4 (3.54 Angstrom, FSC = 0.143; 236,602 particles), protomer A MTR4 core-ZCCHC8 PSP-RBM7 RRM (4.06 Angstrom, FSC = 0.143; 44,800 particles), and protomer B MTR4 core-ZCCHC8 PSP-RBM7 RRM (4.4 Angstrom, FSC = 0.143 37,088 particles).
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
?
Refinement Protocol
?
Refinement Target
?
Overall B Value
?
Fitting Procedure
?
Details
?
Data Acquisition
Detector Type
GATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å
2
)
67.6
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
?
Maximum Defocus (nm)
?
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
?
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
?
Nominal Magnification
?
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
?
Imaging Experiment
Task
Software Package
Version
RECONSTRUCTION
RELION
?
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
?