X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.2 277 50mM Imidazole pH7.2, 12% 2-propanol
Unit Cell:
a: 91.392 Å b: 91.392 Å c: 85.211 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 2.60 Solvent Content: 52.73
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.4800 31.1600 13034 956 97.9000 0.2118 0.2726 42.8404
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.300 40.000 99.400 0.106 ? 10.400 12.300 ? 16406 ? ? 40.910
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.300 2.380 100.000 ? ? ? 10.100 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-D 1.0 APS 21-ID-D
Software
Software Name Purpose Version
HKL-2000 data reduction .
HKL-2000 data scaling .
PHASER phasing 1.3.3
PHENIX refinement 1.19.1
PDB_EXTRACT data extraction 3.27