Planned Maintenance: Some services may turn out to be unavailable from 15th January, 2026 to 16th January, 2026. We apologize for the inconvenience!

SOLUTION NMR


NMR Experiment
Experiment Type Sample Contents Ionic Strength Solvent pH Pressure Temprature (K)
1 2D 1H-15N HSQC 3 mM [U-13C; U-15N] 13C-15N-Thor-profilin, 90% H2O/10% D2O 50 90% H2O/10% D2O 6.5 1 298
2 2D 1H-13C HSQC 3 mM [U-13C; U-15N] 13C-15N-Thor-profilin, 90% H2O/10% D2O 50 90% H2O/10% D2O 6.5 1 298
3 3D 1H-13C NOESY 3 mM [U-13C; U-15N] 13C-15N-Thor-profilin, 90% H2O/10% D2O 50 90% H2O/10% D2O 6.5 1 298
4 3D 1H-15N NOESY 3 mM [U-13C; U-15N] 13C-15N-Thor-profilin, 90% H2O/10% D2O 50 90% H2O/10% D2O 6.5 1 298
5 3D HBHA(CO)NH 3 mM [U-13C; U-15N] 13C-15N-Thor-profilin, 90% H2O/10% D2O 50 90% H2O/10% D2O 6.5 1 298
6 3D HN(COCA)CB 3 mM [U-13C; U-15N] 13C-15N-Thor-profilin, 90% H2O/10% D2O 50 90% H2O/10% D2O 6.5 1 298
7 3D HNCACB 3 mM [U-13C; U-15N] 13C-15N-Thor-profilin, 90% H2O/10% D2O 50 90% H2O/10% D2O 6.5 1 298
NMR Spectrometer Information
Spectrometer Manufacturer Model Field Strength
1 Bruker AVANCE NEO 600
NMR Refinement
Method Details Software
simulated annealing ? 2
NMR Ensemble Information
Conformer Selection Criteria target function
Conformers Calculated Total Number 100
Conformers Submitted Total Number 20
Representative Model 1 (target function)
Computation: NMR Software
# Classification Version Software Name Author
1 structure calculation ? CYANA Guntert P.
2 refinement ? CYANA Guntert, Mumenthaler and Wuthrich
3 peak picking ? CcpNmr Analysis CCPN