7P2Y

ELECTRON MICROSCOPY


Sample

F1Fo ATP synthase

Specimen Preperation
Sample Aggregation State PARTICLE
Vitrification Instrument FEI VITROBOT MARK IV
Cryogen Name ETHANE
Sample Vitrification Details 4ul sample, blotted for 4s at a blotforce of -4.
3D Reconstruction
Reconstruction Method SINGLE PARTICLE
Number of Particles 72317
Reported Resolution (Å) 3.1
Resolution Method FSC 0.143 CUT-OFF
Other Details ?
Refinement Type
Symmetry Type POINT
Map-Model Fitting and Refinement
ID 1
Refinement Space ?
Refinement Protocol ?
Refinement Target ?
Overall B Value ?
Fitting Procedure ?
Details ?
Data Acquisition
Detector Type GATAN K3 (6k x 4k)
Electron Dose (electrons/Å2) 60
Imaging Experiment
Date of Experiment ?
Temprature (Kelvin)
Microscope Model FEI TITAN KRIOS
Minimum Defocus (nm) 1250
Maximum Defocus (nm) 2500
Minimum Tilt Angle (degrees) ?
Maximum Tilt Angle (degrees) ?
Nominal CS 2.7
Imaging Mode BRIGHT FIELD
Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification 85000
Calibrated Magnification ?
Source FIELD EMISSION GUN
Acceleration Voltage (kV) 300
Imaging Details Data collected at Diamond Light Source (Harwell, UK) using Titan Krios G3 and automated alignments using Sherpa. Detector used was Gatan K3 including energy filter.
Imaging Experiment
Task Software Package Version
PARTICLE SELECTION cryoSPARC 2.15
IMAGE ACQUISITION EPU 2.1
CTF CORRECTION cryoSPARC 2.15
INITIAL EULER ASSIGNMENT cryoSPARC 2.15
FINAL EULER ASSIGNMENT cryoSPARC 2.15
CLASSIFICATION cryoSPARC 2.15
RECONSTRUCTION cryoSPARC 2.15
Image Processing
CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION ?