X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.8 293.15 Ammonium sulfate, Tris/HCl, Glutathion, Glycerol
Unit Cell:
a: 70.097 Å b: 61.970 Å c: 70.090 Å α: 90.000° β: 113.000° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.48 Solvent Content: 50.43
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.0500 42.5600 240368 12494 98.5100 0.1381 0.1531 13.2520
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.050 42.560 98.300 0.061 ? 11.460 3.436 ? 253685 ? ? 13.124
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.050 1.080 94.800 ? ? 0.970 2.953 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PETRA III, EMBL c/o DESY BEAMLINE P14 (MX2) 0.827 PETRA III, EMBL c/o DESY P14 (MX2)
Software
Software Name Purpose Version
REFMAC refinement 5.8.0258
XSCALE data scaling .
PDB_EXTRACT data extraction 3.27
XDS data reduction .