7NO2
pdb_00007no2
10.2210/pdb7no2/pdb
Download file
FASTA
PDB
MMCIF
Binary MMCIF
XML
Structure Factors
Full Validation Report
Validation File (XML)
Validation File (CIF)
FASTA Zipped(.gz)
PDB Zipped(.gz)
MMCIF Zipped(.gz)
Binary MMCIF Zipped(.gz)
Structure Factors Zipped(.gz)
Validation File Zipped (.xml.gz)
Validation File Zipped (.cif.gz)
ELECTRON MICROSCOPY
Sample
Rous sarcoma virus - Prague C
Specimen Preperation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
2.5 seconds blotting time
3D Reconstruction
Reconstruction Method
SUBTOMOGRAM AVERAGING
Number of Particles
40962
Reported Resolution (Å)
4.3
Resolution Method
FSC 0.143 CUT-OFF
Other Details
?
Refinement Type
Symmetry Type
POINT
Map-Model Fitting and Refinement
ID
1
Refinement Space
REAL
Refinement Protocol
AB INITIO MODEL
Refinement Target
Correlation coefficient
Overall B Value
?
Fitting Procedure
?
Details
Three copies of CA monomer were rigid body-fitted into the EM density to accommodate the 3 symmetry independent CA copies. The fit was further refined in Coot. The symmetry independent copies were expanded according to the C2 symmetry, and an additional ring of CTDs adjacent to the CA hexamer was added to account for the continuous lattice during the refinement. The model was refined by iterating between automatic real space refinement in Phenix and manual model inspection/editing in Coot.
Data Acquisition
Detector Type
GATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å
2
)
3.5
Imaging Experiment
Date of Experiment
?
Temprature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
1500
Maximum Defocus (nm)
4000
Minimum Tilt Angle (degrees)
?
Maximum Tilt Angle (degrees)
?
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
105000
Calibrated Magnification
?
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
Areas of interest for high-resolution data collection were identified in low magnification montages. Prior to tomogram acquisition, gain references were acquired and the filter was fully tuned. Microscope tuning was performed using the FEI AutoCTF software. The ilumination mode used during acquisition was nanoprobe.
Imaging Experiment
Task
Software Package
Version
VOLUME SELECTION
MATLAB
R2018b
VOLUME SELECTION
IMOD
4.9
VOLUME SELECTION
Dynamo
1.1.333
IMAGE ACQUISITION
SerialEM
?
IMAGE ACQUISITION
DigitalMicrograph
?
CTF CORRECTION
CTFFIND
4.1.10
CTF CORRECTION
IMOD
4.9
CTF CORRECTION
NOVACTF
?
MODEL FITTING
UCSF Chimera
1.13.1
MODEL FITTING
Coot
0.8.9.1
FINAL EULER ASSIGNMENT
Dynamo
1.1.333
CLASSIFICATION
MATLAB
R2018b
RECONSTRUCTION
Dynamo
1.1.333
RECONSTRUCTION
AV3
?
MODEL REFINEMENT
PHENIX
1.18
MODEL REFINEMENT
Coot
0.8.9.1
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION
CTF-correction was initially performed using ctfphaseflip in IMOD and NovaCTF in the final steps